SLC load cell

General Details

Key features:

Load button type load cell

Low height for flexible installation

Wide range loading 0.5 – 75 t

Standard with 2.0mV/V sensitivity and 4-wire connection

Ideal for tank & silo weighing system, platform scale and process weighing machines

Safety overloading: 150%, Breaking Overload: 300%

Fully laser welded for harsh industrial environment

High quality nickel plated with strong corrosion resistant

 

DIMENSIONS

SLC2 dimension

SPECIFICATIONS

Items C3        C4        C5        C6 Unit
Combined error 0.015      0.012      0.01      0.008 %Emax
Rated Capacity 0.5, 1, 2, 3, 5, 10, 20, 30, 50, 75 Ton
Rated Output Analog 2.0mV/V ± 0.1%   Digital 1,000,000d
Zero Output < 1.0 %Cn
Non-linearity < 0.01 %Cn
Repeatability < 0.005 %Cn
Hysteresis Error < 0.015  < 0.0125  < 0.010   < 0.008 %Cn
Creep < 0.015  < 0.0125  < 0.010   < 0.008 %Cn
Temperature Effect on sensitivity(Tkc) < 0.010  < 0.008  < 0.007   < 0.005 %Cn/k
Temperature Effect on zero balance(Tko) < 0.010  < 0.007  < 0.007   < 0.007 %Cn/k
Input Resistance 775 ±10 Ω(Ohms)
Output Resistance 702 ± 2 Ω(Ohms)
Insulation Resistance > 5000 MΩ (50V DC)
Safe Overload 150 %F.S
Breaking Overload 300 %F.S
Working Temperature Range -20~ +70 /-20 ~ +160 °C/°F
Recommended Excitation 8~15 V (DC or AC)
Maximum Excitation 24 V (DC or AC)
Material of elastomer Alloy steel / Stainless steel
Protection level IP68 / IP69 / IP69K
Cable 0.5t~30t: 12m; 40t~75t: 16m;
Standard GB/T7551-2008  OIML R60

WIRING CODE

APPLICATION

SLC2-9