QSZ load cell

General Details

Key features:

Railway scale load cell

Mounting kits support

Extremely accurate

Lighting protection with surge resistor

Auto temperature compensated

Standard with 2.0mV/V sensitivity and 4-wire connection

Ideal for train, railway vehicles

Safety overloading: 150%, Breaking Overload: 300%

Fully laser welded for harsh industrial environment

High quality nickel plated with strong corrosion resistant

DIMENSIONS

QSZ dimensions

SPECIFICATIONS

Items C3        C4        C5        C6 Unit
Combined error 0.015      0.012      0.01      0.008 %Emax
Rated Capacity 10, 20, 30, 40, 50, 60 Ton
Rated Output Analog 2.0mV/V ± 0.1%   Digital 1,000,000d
Zero Output < 1.0 %Cn
Non-linearity < 0.01 %Cn
Repeatability < 0.005 %Cn
Hysteresis Error < 0.015  < 0.0125  < 0.010   < 0.008 %Cn
Creep < 0.015  < 0.0125  < 0.010   < 0.008 %Cn
Temperature Effect on sensitivity(Tkc) < 0.010  < 0.008  < 0.007   < 0.005 %Cn/k
Temperature Effect on zero balance(Tko) < 0.010  < 0.007  < 0.007   < 0.007 %Cn/k
Input Resistance 775 ±10 Ω(Ohms)
Output Resistance 702 ± 2 Ω(Ohms)
Insulation Resistance > 5000 MΩ (50V DC)
Safe Overload 150 %F.S
Breaking Overload 300 %F.S
Working Temperature Range -20~ +70 /-20 ~ +160 °C/°F
Recommended Excitation 8~15 V (DC or AC)
Maximum Excitation 24 V (DC or AC)
Material of elastomer Alloy steel / Stainless steel
Protection level IP68 / IP69 / IP69K
Cable 10klb~50klb: 12m; 75klb~100klb: 16m;
Standard GB/T7551-2008  OIML R60

WIRING CODE

Comments

Enquire Now

Your email address will not be published. Required fields are marked *